Flame pattern

It may take approximately two hours of operation for the logs to achieve their full flame
pattern and glow. During the initial burning in period, some smoke and smell may be
experienced. The appliance should run on the high setting in a well ventilated room until
these dissipate. It is important to check the flame pattern during this time.
Abnormal flame pattern
Abnormal flame performance and/
or pattern can indicate a problem
with your fire, such as blocked gas
injectors, or log set (burn media)
has shifted from when the fire
was first installed. There are some
warning signs that could indicate a
problem.
-
Unusual smell from the
appliance
-
Continued difficulty or delay in
establishing a flame
-
Flame appears either very
short or very long
-
Flame only burns part way
across the burner
-
Severe soot building up on the
inside of the glass door
Important
It is the responsibility of the
installer to check that under
normal conditions of the
appliance, all flue gases are
exhausted to the outside
atmosphere, and that there is no
spillage of combustion gases into
the room.
If the appliance cannot be made
to perform correctly please contact
Rinnai.