Flue Components - Rinnai Arriva Flue Installation Manual

Gas fireplaces
Hide thumbs Also See for Arriva:
Table of Contents

Advertisement

Flue components

Direct A flue kit - R2731
**Arriva only**
Suitable for walls 115-240 mm thick,
typically weatherboard construction.
This is a complete stainless steel
kit with an inbuilt 2° fall to drain
condensate.
80 mm
115-240 mm wall thickness
Direct flue kit - ASPDFK
Suitable for walls up to 385 mm thick (can be cut to length). Can also
be used with ESPIPE900 for longer flueing. The minimum length when
measured from the back plate of the transition casting MUST NOT be less
than 300 mm when joining to other components.
Not pictured is the internal white wall plate, refer render on
50 mm
next page.
Flue pipe - ESPIPE900
Extension pipe used for horizontal,
vertical, and downwards flueing. Can
be cut to size at the non-socketed
end.
Inner is aluminium, outer white PVC.
Comes with a wall bracket, o-ring
(4350), and spacer (4351).
8 | Arriva/Evolve flue installation guide: 10726-I 09-21
Direct B flue kit - R2732
**Arriva only**
Suitable for walls 240-400 mm
thick, typically block construction.
This is a complete stainless steel
kit with an inbuilt 2° fall to drain
condensate.
80 mm
115 mm
(aluminium)
540 mm
Ø 75 mm
Roof terminal - ESROOFCOWL
Roof cowl and connecting pipe for
termination of a vertical flue—can
be cut to size. 500 mm clearance
required from any part of the
building, refer previous page.
Galvanised steel, powder coated
black.
240-400 mm wall thickness
115 mm
Flue transition
25 mm clearance
to combustibles
Arriva adaption flue kit - ASPKIT03
**Arriva only**
Elbow section of this component
(circled) requires a 25 mm clearance
from combustibles. Kit includes:
flue transition (rotates)
condensate trap
wall strap
drain tube (750 mm)
o-ring silicone grease
flue slide stopper (4822)
R1970 sub-kit
R1970 is the condensate drain kit.
This is used for installations that
require draining condensate back
into the fire.
45° flue bends - ESBEND
Two bends in a kit. Can be used
separately, or together as a 90° bend.
Refer additional images on p.26-27.
Spacers are mandatory to
ensure alignment of the flue
and to stop the outer bends
overheating