Novo Dv Flue Components - Rinnai RDV2320MN/L Installation Manual

Table of Contents

Advertisement

Novo DV flue components

Coaxial vertical flue kit 3.6 m
Kit includes:
Coaxial vertical roof cowl
(R3651)
3 x 1200 mm interlocking
flue pipes (R3636)
2 x wall straps (R3647)
If longer flueing is required
order additional lengths of flue
pipe.
Coaxial vertical flue cowl
Aluminium flue terminal
required for all coaxial vertical
flue installations—part of
vertical flue kit.
Ø268 mm
30 | Novo DV inbuilt installation guide: 13748-C 03-22
Flue pipe extensions
75-175 mm:
75-360 mm:
Used for extended straight
lengths of flue. Available in two
lengths—extending to 175 mm
or 360 mm. CANNOT be cut
to size.
Inner: Aluminium Ø100 mm
Outer: Galv. steel Ø170 mm
Coaxial flue pipes DV
Interlocking. CANNOT be cut to size.
Once joined nominal length reduces approximately 35 mm.
Inner:
Outer:
Pipe
R3665
150 mm
230 mm
300 mm
450 mm
600 mm
900 mm
1200 mm 1181 mm
R3651
R3638
R3639
Aluminium (Ø100 mm)
Galvanised steel (Ø170 mm)
Installed
Code
length
114 mm
R3630
191 mm
R3631
267 mm
R3632
419 mm
R3633
572 mm
R3634
876 mm
R3635
R3636
Coaxial 45° flue elbows
Two bends in a kit.
Offsets obstructions. Elbow
swivels 360° at base. Angle
not adjustable. Once joined
effective length reduces
35 mm to approx. 73 mm.
Inner: Aluminium Ø100 mm
Outer: Galv. steel Ø170 mm
108
108
R3642

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdv2320cn/l