Aligning boresight

1. Display the boresight test pattern.
a. Pressing the Test key on the remote keypad or use the built-in keypad and press the soft
key that displays Test on the LCD display.
b. Press the Up Arrow key to cycle to Boresight.
c. Press Enter.
2. Focus the image on cross-hair image I.
3. Evaluate the focus on cross-hair image II and III.
If all three images are in focus, no further action is required.
If boresight is required, continue to step 3.
The adjustment screws on the lens mount affect the corresponding cross-hairs on the test
pattern. The cap screw (B) may be under a plastic cap. Remove and retain before adjusting.