FNM HPE 300 Owner's Manual page 40

Marine diesel engine
Table of Contents

Advertisement

General Information
'
O
M
WNER
S
ANUAL
HPE 300
Marine Diesel Engines
Synchro mode operation
IMPORTANT: This function is available only for two-engine systems.
It is possible to command both engines at the same speed and direction with only one lever.
With both levers in neutral position, press the Engine buttons at the same time for 3 seconds. The
command of both engines is now on the right lever. In Synchro mode operation the Warm/Sync and
Command LEDs are always lighted on, except for the neutral position where all the LEDS are
permanently ON.
Position both levers in neutral, and press the Engine buttons for 3 seconds at the same time and the
command of each engine is again assigned to the respective lever and the Warm/Sync LED is switched
off.
Trim control unit (stern drive application)
Double station Single station
The trim command can be activated by the Command Station by means of the "+" and "-" buttons. The
command signals are transferred to the Actuator from the Command Station. The relay board
mounted in the actuator enables the in-trim, trim-out and trailer functions.
The "+" and "-" buttons pressed together for at least 3 sec. activate the trailer function that allows to pull
the stern drive totally out of water.
Emergency lever
B
In an emergency you can quickly disable the electronic system and command the propulsion engines
directly with the emergency mechanical levers that are already mounted on the actuator. Just totally
unscrew the knob A. This procedure will allow you to control the gearbox manually, using the levers B,
and with gas to a minimum.
A
ID Labels
B
Under the base of each command station a level there are n. 2 labels with the serial number and the code
of the command station.
A
ENG rel. 1/11
www.fnm-marine.com