HARVEST SEQUENCE WATER PURGE

The Harvest sequence water purge adjustment may
only be used when the ice machine is hooked up to
special water systems, such as a reverse osmosis or
de-ionized water treatment system.
Disconnect electric power to the ice machine at the
electrical disconnect before proceeding.
The Harvest sequence water purge is factory-set at 45
seconds. A shorter purge setting (with standard water
supplies such as city water) is not recommended. This can
increase
requirements.
The Harvest sequence water purge may be set to
0 or 45 seconds. Repositioning the jumper will set
the harvest water purge to 0 seconds. This setting
does not affect the SeCs or AuCS (cleaning)
sequences.
During the Harvest sequence water purge, the
water fill valve energizes and de-energizes by
time. The water purge must be at the factory
setting of 45 seconds for the water fill valve to
energize during the last 15 seconds of the water
purge. If it is set to 0 seconds, the water fill valve
will not energize during the water purge.
Part Number 80-1505-3 6/11
!
Important
water
system
45 second
setting
Warning
cleaning
0 second
setting
and
sanitizing