Ice Machine Operation

HARVEST SEQUENCE WATER PURGE

The harvest sequence water purge adjustment may be
used when the ice machine is hooked up to special
water systems, such as a de-ionized water treatment
system.
Disconnect electric power to the ice machine at the
electrical disconnect before proceeding.
The harvest sequence water purge is factory-set at
45 seconds. A shorter purge setting (with standard
water supplies such as city water) is not
recommended. This can increase water system
cleaning and sanitizing requirements.
The harvest sequence water purge is factory set.
Repositioning the jumper will set the harvest water
purge to 0 seconds. This setting does not affect the
SeCs or AuCs (cleaning) sequences.
3-6
!
Warning
Important
During the harvest sequence water purge, the water
fill valve energizes and de-energizes by time. The
water purge must be at the factory setting of 45
seconds for the water fill valve to energize during the
last 15 seconds of the water purge. If it is set to less
than 45 seconds, the water fill valve will not energize
during the water purge.
Water Purge Adjustment
For your safety and to eliminate errors, we recommend
that a qualified service technician make the harvest
water purge adjustment.
Section 3
45 second
setting
0 second
setting
SV3139
SV3140
Part Number 000000966 03/09