G. Remove the water pump.
•
Note position of water pump outlet, and then
disconnect vinyl hose from the pump outlet.
•
Rotate the thumbscrew that secures the pump to
the bulkhead 1/4 turn clockwise.
•
Rotate the water pump assembly 1/4 turn
counterclockwise.
•
Lower the pump assembly into the evaporator
compartment.
•
Disconnect the water pump power cord.
•
Remove water pump assembly from ice
machine.Do not soak the water pump motor in
cleaner or sanitizer solution
H. Remove the bin thermostat probe
•
Loosen the 2 screws that holds the probe in place.
The probe can easily be cleaned at this point
without complete removal.
NOTE: Proceed to page 101, Step 7.
Part Number 80-1505-3 6/11