Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
Step 1 Remove front door and top cover. This will
allow easiest access for adding cleaning and
sanitizing solutions.
Step 2 Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Never use anything to force ice from the
evaporator. Damage may result.
Step 3 Remove all ice from the bin/dispenser.
Step 4 Place the toggle switch in the CLEAN
position. The water will flow through the water dump
valve and down the drain. Wait until the water trough
refills and water flows over the evaporator, then add
the proper amount of ice machine cleaner.
Model
S0600C/S0680C/S0800C
S1000C/S1200C
IB620C/IB680C/
IB820C/IB1020C
S1470C/S1870C/
S2070C/S2170C
S3070C
86
! Caution
Amount of Cleaner
5 ounces (150 ml)
5 ounces (150 ml)
9 ounces (270 ml)
16 ounces (475 ml)
Part Number 80-1505-3 6/11