11. Charge the system with the proper refrigerant to
the nameplate charge.
12. Operate the ice machine for one hour. Then,
check the pressure drop across the suction line
filter-drier.
A. If the pressure drop is less than 2 psig, the
filter-drier should be adequate for complete
cleanup.
B. If the pressure drop exceeds 2 psig, change
the suction line filter-drier and the liquid line
drier. Repeat until the pressure drop is
acceptable.
13. Operate the ice machine for 48-72 hours. Then
remove the suction line drier, replace with suction
filter and change the liquid line drier.
14. Follow normal evacuation procedures.
Part Number 80-1505-3 6/11
227