Refrigeration System Installation - Manitowoc QuietQube SD0672C Technician's Handbook

S model & ice beverage ice machines
Hide thumbs Also See for QuietQube SD0672C:
Table of Contents

Advertisement

REFRIGERATION SYSTEM INSTALLATION

QuietQube®
Ice Machine
S0600C
IB0620C
S0680C
IB0680C
S0850C
IB0820C
S1000C
IB1020C
S1200C
IB1020C
S1470C
S1870C
S2070C
S2170C
S3070C
*Line Set
RC 21/31/51
RC 20/30/50**
RC 23/33/53
RC 24/34/54
**NOTE: The CVD2075 has a suction line fitting of 7/8" and a
liquid line fitting of 5/8". Since the line set is sized differently,
please use the provided bushings to properly connect the line
set to the CVD condensing unit.
Part Number 80-1505-3 6/11
Remote Single
Circuit
Condenser
CVD675
CVD685
CVD885
CVD1085
CVD1285
CVD1185
CVD1285
CVD1075
CVD1485
CVD1486
CVD1885
CVD2075
CVD2085
CVD3085
Suction
Line
5/8 in.
(15.9 mm)
3/4 in.
(19.1 mm)
3/4 in.
(19.1 mm)
Two Lines -
3/4 in.
(19.1 mm)
Line Set*
Liquid
Line
3/8 in.
(9.5 mm)
1/2 in.
(12.7 mm)
5/8 in.
(15.9 mm)
One Line -
5/8 in.
(15.9 mm)
RC-21
RC-31
RC-51
RC-20
RC-30
RC-50
RC-23
RC-33
RC-53
RC-24
RC-34
RC-54
Insulation
Thickness
Suction Line
1/2" (13mm)
Liquid Line
1/4" (7mm)