Section 2

Remote Condenser and Condensing Unit Refrigeration System Installation

Each ice machine head section ships from the factory with a refrigerant charge
appropriate for the entire system operation. The serial tag on the ice machine indicates
the refrigerant charge.
QuietQube® Ice
Machine
IF0600C
IBF0620C
IBF0820C
IF0900C
IBT1020C
IT1200C
IF1400C
IF1800C
IF2100C
*Line Set
RC 21/31/51
RC 20/30/50
RC 23/33/53
n
Installation of a QuietQube® Condensing
Unit may require the use of special
equipment for placement. Trained and
qualified personnel are required for proper
rigging and lifting. Holes are provided on
the corners of the condensing unit to allow
the use of lifting shackles.
Part Number 000014141 Rev 07 2/20
Remote Condenser
CVDF0600
CVDF0900
CVDT1200
CVDF1400
CVDF1800
CVDF2100
Suction Line
5/8 inch
16 mm
3/4 inch
19 mm
3/4 inch
19 mm
Warning
Line Set*
RC-21
RC-31
RC-51
RC-20
RC-30
RC-50
RC-23
RC-33
RC-53
Liquid Line
Minimum Insulation Thickness
3/8 inch
10 mm
1/2 inch
13 mm
5/8 inch
16 mm
Manitowoc remote systems are only
approved and warranted as a complete
new package. Warranty on the refrigeration
system will be void if a new ice machine
head section is connected to pre-existing
(used) tubing or condensing units or vice
versa.
Additional Refrigerant
Charge for 50' to 100'
(15 to 30 Meter) Line Sets
1.5 lbs - 680 g
2 lbs - 907 g
2 lbs - 907 g
2 lbs - 907 g
2 lbs - 907 g
2 lbs - 907 g
4 lbs - 1814 g
1/2" (13 mm) Suction Line
1/4" (7 mm) Liquid Line
1/2" (13 mm) Suction Line
1/4" (7 mm) Liquid Line
1/2" (13 mm) Suction Line
1/4" (7 mm) Liquid Line