Solar Panel
Receiver
Aerial
Tamper
switch
6V 1.2Ahr
rechargeable
battery
9V PP3 initial
power up battery
Siren
the Solar Siren. It is therefore important to mount the
Solar Siren a minimum distance of 1m radius away
from any external or internal metalwork, ie. external
drain pipes, gutters and internal radiators, mirrors etc.

INSTALLATION

Remove the holding screw from the base of the housing
and carefully hinge off the front cover. All electronic
components are housed within the front cover.
Use the rear back-plate as a template to mark the
position of the four fixing holes on the external wall. Drill
four 5mm diameter holes and insert the plastic wall plugs.
Mount the back-plate using the four screws provided.

SETTINGS

Undo the three screws holding the miniature switch
cover in place and remove the cover.
SIREN CODE
Under the cover you will find a series of two position
miniature dip switches.
Using a ball-point pen set the miniature dip switches
1-8 to a random sequence of 'ON's' and 'OFF's'.
Make a note of the Siren Code miniature switch
settings as this will be needed when setting the siren
transmitter in the Control Unit.
DO NOT SET THE "SIREN CODE" TO THE "HOUSE
CODE" USED IN THE DETECTORS.
12
Front cover
locating tabs
Miniature
switch cover
Printed circuit
board enclosure
Optional Strobe
Upgrade PCB
Note: When the Solar Siren is viewed as shown above
the miniature switches are 'upside down'.
ON
1
2
(Always change from the factory setting)
ALARM DURATION
This is the maximum length of time that the Solar Siren
alarm will sound for, following activation. Alarm duration
can be set for either 3 or 15 minutes. Set miniature
switch 9 'OFF' for 3 minutes or 'ON' for 15 minutes.
Refit the miniature switch cover securely.
Note:
Following activation into alarm condition the
Solar Siren will continue to sound until either the Control
Unit is Disarmed, or the Control Unit Auto Stop time
expires, or until the Solar Siren Alarm Duration Time
expires; whichever occurs first.

INITIAL POWER-UP

Once you have completed setting your Siren Code and
Alarm Duration Time, connect the 9 Volt PP3 initial
Power-up Battery to the clip-on connectors. Connect
the Rechargeable Battery to the charging leads red to
red (+) and black to black (-).
Hinge the front cover locating tabs over the top edge of
the back-plate, push the base of the Siren cover into
place and secure with the lower fixing screw.
7.5 V DC
charging adaptor
input
Siren Code
miniature switches 1-8
Alarm duration
miniature switch 9
View of inside
Alarm Duration DIP Switch 9
3
4
5
6
7
8
Siren Code
Protector P500S