B.5. Cooling Module Specifications
Specification
Max. Air Flow (each
module)
Input Power
Input Current
Rated Voltage
Acoustic Noise
Temperature
B.6. RAID Management
Specification
Configuration
Performance Monitoring
Remote Control and
Monitoring
Event Broadcast/Alert
Event Notification
Hardware Connection
Configuration on Disk
Failure Indicator
Cooling Module Specifications
High speed: 90 CFM
Low speed: 70.7 CFM
9W max.
0.89A max.
DC 12V
High speed: 51dB max.
Low speed: 46 dB max.
Operating: -10 to +60ºC
Storage: -20 to +70ºC
•
Text-based firmware-embedded utility over RS-
232C through the included serial cable
•
LCD keypad panel
•
The RAIDWatch Manager program using in-band
or Ethernet connection
Yes
Yes
Yes (via Java-based RAIDWatch Manager)
Yes (via RAIDWatch's sub-module, Configuration
Client or NPC)
In-band over Fibre, Ethernet, or RS-232C
Configuration data stored on disk drives for logical
drive assemblies to exist after controller replacement;
basic settings, e.g., channel mode settings, are stored
on NVRAM
Via audible alarm, LCD keypad panel, RAIDWatch
Manager session, event notifications, or event prompts
on terminal emulation
Appendix B Specifications
B-5