HEATER AND REFRIGERANT SYSTEM
CONDENSER
Removal / Installation
1. Discharge the refrigerant from the system.
2. Remove the fresh-air duct.
3. Remove the radiator brackets.
(Refer to the 1996 626/MX-6 Workshop Manual, section E.)
4. Disconnect the pipes from the condenser.
5. Insert a protector (such as cardboard) between the con
denser and the radiator.
6. Remove the condenser as shown in the figure.
7. Install in the reverse order of removal. Apply clean
compressor oil to the O-rings before connecting the fit
tings; do not apply compressor oil to the fitting nuts.
When installing a new condenser, add 15 ml {15 cc, 0.5
fl oz} of compressor oil through the high-pressure side
of the condenser.
Inspection
Check for the following and repair or replace the con
denser as necessary.
1. Cracks
2. Bent fins
3. Distorted or damaged condenser inlet or outlet
G
G— 59