Routing the Scanner Drive Cable
Route the cable in the order indicated (q through o), and adjust the mirror position as shown on the
following page.
2
Set the mirror
positioning tool.
9
32±1mm
Loosen the set screws
to free the pulley rotation.
Set screws
7
8
5
6
Figure 2-207
STANDARDS AND ADJUSTMENTS
Put the steel ball into the hole of the pulley.
Wind the cable toward the inside 3.5 times
and then toward the outside 6 times; then,
fit the pulley clip.
3
Pulley clip
Steel ball
1
4
2
2–3