CHAPTER 4 TROUBLESHOOTING MALFUNCTIONS

1

E000 (Fixing temperature fails to rise.)

Cause
Step
Thermistor
1
relay connector
(J50; discon-
nected)
Thermistor
2
(open circuit)
Heater (open
3
circuit)
Thermistor
4
(poor contact)
Fixing heater
5
driver
DC controller
PCB
Checks
Clear the error using 'ERROR'
in service mode (*4*).
Is the connection of the con-
nector J50 (4-wire harness
under the counter mount)
good?
Let the fixing assembly to cool;
then, disconnect J50, and mea-
sure the resistance of the ther-
mistor. Is the reading as fol-
lows?
J50-1/-2 (yellow line):about
1388 k
J50-3/-4 (white line):about
3636 k
Disconnect the connector J4
(near the door switch assem-
bly), and check electrical conti-
nuity. Is there electrical continu-
ity?
Replace the fixing assembly. Is
the problem corrected?
Replace the fixing heater dri-
ver. Is the problem corrected?
TROUBLESHOOTING MALFUNCTIONS
Yes/No
Action
NO
Re-connect it.
NO
Replace the fixing assembly.
NO
Replace the fixing assembly.
YES
End.
YES
End.
NO
Replace the DC controller DC
PCB.