Canon GP215 Service Handbook page 14

Hide thumbs Also See for GP215:
Table of Contents

Advertisement

STANDARDS AND ADJUSTMENTS
6
Installing the Scanning Lamp
Install the scanning lamp with the following in
mind:
1. Make sure that the side with the manufactur-
er's name is toward the rear of the machine.
2. Make sure that the transparent side of the
lamp faces the reflecting plate.
3. Do not touch the transparent surface.
Reflecting plate
Figure 2-211
7
Positioning the Multifeeder
Paper Guide Cam
Adjust so that the paper guide plate cam is as
shown when the solenoid plate is in contact with
the claw of the control ring.
Gear 1
Paper guide plate
Gear 2
Paper guide plate
Figure 2-212
2–6
Transparent surface of
scanning lamp
Control ring
Stop screw
w/hex hole
Claw
Solenoid plate
8
Attaching the Timing Belt of
the Multifeeder Assembly
1) Butt the side plate of the multifeeder against
both ends (section A; open condition).
2) Move the slide volume to the center (in the
direction of B), and attach the timing belt to
the pulley.
Timing belt
Rack plate
Pulley
B
Slide volume
Figure 2-213
Pulley
Section A

Advertisement