E240; Processor Pcb); E243 (Error In Communication Between Control Panel And Image Processor Pcb.) - Canon GP215 Service Handbook

Hide thumbs Also See for GP215:
Table of Contents

Advertisement

TROUBLESHOOTING MALFUNCTIONS
18
E240 (error in communication between DC controller PCB and image

processor PCB)

Cause
Step
1
Connector
2
(poor contact)
DC controller
3
PCB
Image proces-
sor PCB
19
E243 (error in communication between control panel and image proces-
sor PCB)
Cause
Step
1
Connector
2
(poor contact)
Control panel
3
Image proces-
sor PCB
4–12
Checks
Turn OFF/ON the main power.
Is the problem corrected?
Is the connection of the con-
nector J111 on the DC con-
troller PCB and the connector
J509 on the image processor
PCB good?
Replace the DC controller
PCB. Is the problem corrected?
Checks
Turn OFF/ON the main power
supply. Is the problem correct-
ed?
Is the connection of the con-
nector J517 on the image
processor PCB and the con-
nector J905 on the control
panel good?
Replace the control panel. Is
the problem corrected?
Yes/No
NO
End.
YES
Connect the connector proper-
ly.
YES
End.
NO
Replace the image processor
PCB.
Yes/No
YES
End.
NO
Connect the connector proper-
ly.
YES
End.
NO
Replace the image processor
PCB.
Action
Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp200