Function Menus; Maximum, Minimum, Individual Values Memory - Ahlborn ALMEMO 2590-2 Operating Instructions Manual

Universal measuring instruments and data loggers
Table of Contents

Advertisement

11. FUNCTION MENUS

To manage individual tasks each measuring
menu can be assigned a function menu from
the adjacent list. For each measuring operation
you can at any time toggle between measuring
menu and function menu.
To call up function menu selection in menu selection see 9
or in measuring menus and function menus press key(s) :
To select function menu press key(s) :
To clear the function menu press key(s) :
Navigation through several function menus :
To toggle between function menu and measuring menu :

11.1 Maximum, minimum, individual values memory

The function menu
shows not only the measured value
memory
but also the continuously acquired maximum
and minimum values for the selected measuring
point plus a memory for 100 individual values.
Maximum value, minimum value :
Function Min and Max :
To clear select the function (see 8.4):
To clear maximum, minimum, and average values for all channels press :
As soon as you clear the memory, the current measured value will appear (be-
cause measuring is continuous). Each time a measuring operation starts, if the
device has been so configured, the peak values will be cleared ; (for default
setting see 13.8).
Individual values memory
Each measured value can be saved at the touch of a button. The measured
value is displayed together with its units and position number in the
function. Either just the last value or the whole memory can be cleared. All
saved data can be shown on the display or output as a list to the interface.
To continuously save the measured value press key :
Memory display with position :
To clear the last position after function selection press key :
To clear all saved values press key :
To display all saved values press key(s) :
To output all saved values press key :
max, min, individual values
Function menus
Function menus
max, min, ind. val memory ©
Averaging
Two-point adjustment
Scaling
Data logger function s
Mªª
F
< FCT >
and
< CLR >
< ►F >
or
< F◄ >
and
< M◄◄ >
25.45 °C
00:
NTC
Temperature
Min:
25.37
Max:
Memory :
P12:
MEM
Mªª
M LISTM FCT
Min:
25.37
Max: 31.34
Min:
25.37
Max: 31.34
<MEM>
Memory:
P12:
<CLRP>
<CLRM>
and
<LISTM>
<F ►>
<PRINT>
ALMEMO
®
2590
©
CLR
or
PROG
< ►►F >
31.34
25.45 °C
<CLRA>
memory
25.45 °C
31