PtRh13-Pt (R)
ITS90
PtRh30-PtRh6 (B)
ITS90
Au-FeCr
W5Re-W26Re (C)
++
NTC type N
NTC type N
++
PTC type Kty84
++
Millivolt 1
Millivolt
Millivolt 2
Volt
Difference - millivolt 1
Difference - millivolt
Difference - millivolt 2
Difference - volt
Sensor voltage
Milliampere
Percent (4 to 20 mA)
Ohms
Kilohms
++
Frequency
Pulses
Sensors / transducers
Digital input
Digital interface
Rotating vane, normal 20
Rotating vane, normal 40
Rotating vane, micro 20
Rotating vane, micro 40
Rotating vane, macro
Water turbine, micro
Dyn. pressure 40 m/s with TC and PC
Dyn. pressure 90 m/s with TC and PC
Flow sensor SS20
++
Relative atm. humidity, capacitive
Rel. atm humidity, capacitive, with TC
Rel. atm. humidity, capacitive, with TC
Humid temperature HT
Conductivity probe with TC
CO
sensor
2
O
saturation with TC and PC
2
O
concentration with TC
2
Function channels (see 12.10)
Selecting the measuring range
ZA 9000-FS
ZA 9000-FS
+400.0...+1800.0
ZA 9000-FS
ZA 9000-SSC
ZA 9000-FS
ZA 9040-SS3
ZA 9040-SS4
ZA 9000-FS
-26.000...+26.000
ZA 9000-FS
-10.000...+55.000
ZA 9000-FS
-260.00...+260.00
ZA 9000-FS
-2.0000...+2.6000
ZA 9000-FS
-26.000...+26.000
ZA 9000-FS
-10.000...+55.000
ZA 9000-FS
-260.00...+260.00
ZA 9000-FS
-2.6000...+2.6000
any
ZA 9601-FS
-26.000...+26.000
ZA 9001-FS
ZA 9000-FS
ZA 9003-SS4
ZA 9909-AK
ZA 9909-AK
Connector /
Measuring range Units Display
cable / sensor
ZA 9000-EK2
ZA 9919-AKxx
-65000... +65000
FV A915-S120
FV A915-S140
FV A915-S220
FV A915-S240
FV A915-MA1
FV A915-WM1
FD A612-M1
FD A612-M6
ZA9602-SSS
FH A646
FH A646-C
FH A646-R
FN A846
FY A641-LF
FY A600-CO2
FY A640-O2
FY A640-O2
0.0...+1760.0
-270.0...
+60.0
0.0...+2320.0
-30.00...+125.00
0.000...+45.000
-0.0...+200.0
0.00...20.00
0.00... 100.00
0.00... 400.00
0.00... 110.00
0... 25000
0... 65000
0.0... 100.0
0.30... 20.00
0.40... 40.00
0.50... 20.00
0.60... 40.00
0.10... 20.00
0.00... 5.00
0.50... 40.00
1.00... 90.00
0.50... 20.00
0.0... 100.0
0.0... 100.0
0.0... 100.0
-30.00...+125.00
0.0 ...20.000
0.0 ... 2.500
0 ... 260
0 ... 40.0
ALMEMO
®
2590
°C
Pt13
°C
EL18
°C
AuFe
°C
WR26
°C
NTC
°C
NTC3
°C
KTY
mV
mV 1
mV
mV
mV
mV 2
V
Volts
mV
D 26
mV
D 55
mV
D260
V
D2.6
V Battery
mA
mA
%
%
Ohms
Ohm4
kΩ
Hz
Freq
pulses
Input
%
DIGI
m/s
S120
m/s
S140
m/s
S220
m/s
S240
m/s
L420
m/s
L605
m/s
L840
m/s
L890
m/s
L920
%H
rH
%
%H
HcrH
%H
H rH
°C
P HT
mS
LF
CO2
%
O2-S
%
O2-C
mg/l
51