20 February, 2001
Magnification
Main Scan Magnification
1. Place the A3 test chart on the exposure glass and make a copy from one of the
feed stations.
2. Check the magnification ratio. If necessary, adjust the magnification using the
following SP mode.
Main Scan Magnification
Sub-scan Magnification
1. Place the OS-A3 test chart on the exposure glass and make a copy from one of
the feed stations.
3. Check the magnification ratio. If necessary, adjust the magnification using the
following SP mode.
Sub-scan magnification
COPY ADJUSTMENTS: PRINTING/SCANNING
A
B
A: Main scan magnification
B: Sub-scan magnification
B039R517.WMF
SP mode
Specification
SP4-008
SP mode
Specification
SP4-101
3-53
± 1.0%
± 1.0%