18. The display shows "HH-04". Press the PRINT/ACCUMULATE button. The display
will show "00000" with the far right number flashing. Use the LOCAL/TOTAL button
to advance the number and the ZERO button to move the number flashing to the
left. Enter the value of the forth load and press the PRINT/ACCUMULATE button
when the value of the forth load is displayed.
19. The display shows "LL-04". Apply the forth load to the scale. With the forth load
applied to the scale press PRINT/ACCUMULATE button.
Repeat step 12 and 13 for each additional "HH-05" – "HH-10" and "LL-05"- "LL-10"
combination. If the scale is turned off at any time the calibration data acquired to that
point will be retained. After the PRINT/ACCUMULATE button is pressed after "LL-10",
the display will return to normal weighing.
Following calibration, replace the strap to shorting pins 2 and 3 (RUN); replace the
assembly and reattach the assembly with the screws. This will ensure that the
calibration information of the scale is protected from being changed.
Note: Care must be taken to ensure the wire harness is seated properly to
prevent it from being pinched between the display assembly and the scale
casing.