C) How to set CONTINUOUS Timer (reset Timer)
1) Press TIMER button
TIMER CONT. display goes off.
2) Press the ON/OFF key. The LED lights and the operation starts with OPERATION displayed
on the liquid crystal display.
3) The unit will continuously operate until the ON/OFF key is pressed, or TIMER ON/OFF
operations restarted.
Note: For daily or weekly control there is the RBC-WT1-PE (7-Day Timer).
To Stop the Timer Operation
G
Push the ON/OFF button.
The LED goes off and the air conditioner stops, even if the set time is not reached.
G
The set ON or OFF will be saved.
G
To Clear the Timer
G
Push the TIMER button.
When the TIMER is pressed, the timer operation is suspended.
G
To Change the Set Time
Follow steps 1 and 2 above. Pressing ON/OFF will then adjust the timer.
G
The operation LED illuminates and the newly set timer operation starts.