6. THE REMOTE CONTROLLERS
OUTLINE OF SPECIFICATION
1. When this button is pushed once, the air conditioner
is turned on, with this operation lamp coming on.
2. If pushed once more, it will be turned off, the
ON/OFF
operation lamp going off.
1. Each time this is pressed, the display
changes in the following sequence:
FAN ONLY – COOL – HEAT – AUTO
1. Each time this is pressed, the display
changes in the following sequence:
AUTO – HIGH – MED – LOW
1. When this is pressed, the louvers will start
oscillation and the display will illuminate.
2. When it is pressed again, the louvers will stop.
1. These buttons are used to set the required room
temperatures.
1. When the TIMER ADJUST button is pressed once,
the time changes 10 minutes. If the button is held,
the time changes in 1 hour steps.
2. If the operation LED is illuminated, the timer
operation will start on completion of the setting.
3. If the operation LED is not illuminated, the timer
operation will start on the operation of the ON/OFF
button.
4. The remaining time can be seen throughout the
timer operation.
1. This display appears when the air conditioner is in
the CHECK mode.
2. Use the CHECK button for a malfunction check.
1. This display appears after 2500 hours of operation.
Unit LAN address can be set using the [FILTER]
button.
1. Press and hold the [FILTER] button for 5 seconds.
The LCD display should change, as shown below:
2. U
se the TIMER ADJUST button to select required address.
3. Press [FILTER] again to save address.
Note: This facility is enabled by SW02 BIT7=OFF on
1. By pressing the RESET Key, the remote controller is
reset by way of hardware. (The setting/display are in
initial values with the check memory cleared.)
www.heronhill.co.uk
the indoor PCB (Factory Default).
78
REMARKS
For models with
automatic louvers
only, otherwise:
will be displayed.
˚
18-29
C
Control range
On Timer or
Off Timer only.
CHECK and FILTER
buttons are for the
use of Service
Engineers.
Use a pointed object
to operate the
RESET Key.