DUAL CODEC SETUP
REC/PB > DUAL CODEC SETUP
Note:
When a setting other than "NORMAL" is selected in the "REC/PB FUNCTION" - "RECORDING" setting menu item (➝ page 90), or when
"ON" is selected in the "SIMUL REC" item (➝ page 90), proxy recording cannot be performed even if "CODEC USAGE" is set to
"PROXY REC(P2)" or "PROXY REC(P2&SD)."
Item
Selects the media for proxy data recording.
PROXY REC (P2): Records proxy data to a P2 card.
PROXY REC (P2&SD): Records proxy data to both a P2 card and SD memory card.
CODEC USAGE
STREAMING: Outputs streaming data.
OFF: Proxy data recording and streaming output are not performed.
If CODEC USAGE cannot be changed, change the PROXY REC MODE or STREAMING
MODE setting.
Sets the recording mode for proxy data.
LOW 2CH MOV (Only in 1080i mode)
HQ 2CH MOV
PROXY REC MODE
SHQ 2CH MOV
AVC-G6 2CH MOV
For details on each mode, refer to "Recording modes and recording signals (video and au-
dio)" (➝ page 33).
Sets the streaming transfer mode.
STREAMING
LOW
MODE
HQ
AVC-G6
TC/UB/CTL
REC/PB > TC/UB/CTL
Item
Selects the 12- or 24-hour format for the CTL counter display.
CTL DISPLAY
±12h: 12-hour format display
24h: 24-hour format display
Sets the operating mode of the internal time code generator.
REGEN:
Synchronizes the internal time code generator to maintain continuity with the last time code
recorded on the P2 card.
TCG MODE
PRESET:
Starts recording from the value set with the [TC PRESET] button.
EXT:
Uses the external time code input from the TIME CODE IN connector or VITC or SLTC of the
video signal. Set the selection in the "EXT TC SEL" (➝ page 93) menu item.
Sets the operating mode for the user bits of the internal time code generator.
REGEN:
Synchronizes the internal time code generator with the last user bit recorded on a P2 card.
PRESET:
UBG MODE
Starts recording from the value set with the [TC PRESET] button.
EXT:
Uses the external UB input from the TIME CODE IN connector or VITC or SLTC of the video
signal. Set the selection in the "EXT TC SEL" (➝ page 93) menu item.
Sets the operating mode for advancing the internal time code generator.
REC RUN: Advances the internal time code generator only during recording.
RUN MODE
FREE RUN: Advances the internal time code generator while the power is on regardless of
the operating mode.
92
Setup Menu: Menu List
Settings and brief function description
Settings and brief function description
_ is the factory default setting.
FREQ indications
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
_ is the factory default setting.
FREQ indications
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz