I. SELECTING THE SITE
Keep the following in mind when selecting the site of installation; if possible, pay a
visit to the user's before the delivery of the copier:
1. There must be a power outlet that satisfies the required power ratings and that may
be used exclusively for the copier.
2. The temperature must be between 7.5°/45.5F and 32.5°C/90.5F and the humidity,
between 5% and 85%. In particular, avoid areas near water faucets, water boilers,
humidifiers, and refrigerators.
3. Avoid areas near sources of fire and areas subjected to dust or ammonium gas.
Avoid direct rays of the sun; provide curtains as necessary.
4. The level of ozone generated when the copier is in operation will not affect the health
of the individuals near it. However, since some may find it unpleasant, be sure that
the room is well ventilated.
5. The floor must be flat so that the feet of the copier will remain in contact and the
copier will be kept level.
6. The space must be large enough to allow at least 10cm/3.9". from all walls so that
the copier may be operated without obstacles.
7. The site must be well ventilated. If multiple copiers are installed, be sure that the
exhaust from other copiers will not flow into the copier.
Be sure not to install the copier near air inlets used for ventilating the room.
Note:
Generally, silicone gas (vapors of silicone oil from the fixing assembly) emitted by
a copier soils corona charging wires, making the life of the wires shorter. This is
more conspicuous in a low humidity environment.
COPYRIGHT © 1997 CANON INC.
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
50 cm / 19.5 " min.
Copier
Figure 9-101
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)

CHAPTER 9 INSTALLATION

10 cm / 3.9 " min.
50 cm / 19.5" min.
50 cm / 19.5 " min.
9-1

Advertisement

Table of Contents
loading

Table of Contents