I.
SELECTION
OF INSTALLATION
LOCATION
The
copier
should
be installed
in a
location that meets the following
require-
ments. It is recommended
that the service
technician
personally
inspect
the
cus-
tomer's
premises
before
installing
the
copier.
A. The location
should have an electric
B.
C
outlet capable of supplying the voltage
shown on the rating plate (& 10%) and
a current of at least 15A. The copier
must be grounded. (AB-pin plug must be
used.)
The
ambient
temoerature
should
be
within the range 7.5 to 32.5"C (45 to
90°F) and the relative humiditv between
10 and 85%. The copier should not be
installed
near
water
faucets,
space
heaters, humidifiers, or refrigerators.
The copier should not be installed close
to a naked flame or in a dustv area. or
where
it will be exposed to ammonia
fumes or direct sunlight. If it must un-
avoidably
be installed
beside a sunlit
window,
place
protective
curtains
across the window to block the light.
D. The room should be well ventilated.
E. Make sure that the copier is installed on
a level surface with all of its feet in
contact with the floor.
F. The rear of the copier should be at least
1OOmm (4") away from the wall, with
enough
space at the ends to permit
unrestricted
operation.
COPYAIGHT
0
1988 CANON INC
2m
min
_
(78.7"l
Figure 5-1
L
2.5m
mir
-
(98.4")
Figure 5-2 Copier with sorter installed