Advertisement

Snap 3 piece airflow duct
together using stand out pins
3.
c. Insert the LPS support into the rack stand and align the pins with the holes.
d. Lift the LPS into the frame.
e. Remove the bottom 10 panels from the back of the rack stand.
f. Assemble the three piece airflow duct (supplied with LPS). See Figure 2-4. First snap the 2 "L"
shaped parts together, and then snap this into the 6 stand out pins of the third piece (flat panel).
g. Position the airflow duct directly behind the LPS.
CAUTION!
the lamp power supply that will restrict airflow. See
Figure 2-5.
h. Insert the airflow duct into the rack stand from the out-
side. See Figure 2-4.
i. Secure the airflow duct to the rack stand using the
screws from the rack stand panels.
j. Wire all of the components in the rack stand and
replace the side panel.
k. Twist LPS cable 12 twist/meter.
CP4230 Setup Guide
020-100669-03 Rev. 1 (05-2014)
Figure 2-4 Steps to Installing LPS
Do not install any components in front of
Section 2: Installation and Setup
2.
Lift LPS into frame
1.
Insert support frame
Figure 2-5 Steps to Installing LPS
Keep
Clear
2-7