2. Connect the Lamp Leads:
a. Open the LVPS access door and use a 3 mm driver to remove the four M4 hex head screws from the
safety cage front panel. Lift the front panel over the igniter.
b. Loosen the 6 screws to remove the LPS side panel.
c. Route the cables through the strain reliefs in the LPS cover.
d. Connect the positive (+) and negative (-) lamp leads to the terminals on the LPS.
e. Tighten the strain reliefs.
f. Route the positive and negative leads from the LPS through the two strain reliefs in the cinema projec-
tor baseplate.
Igniter make sure the black (-) power cable (cathode lead) is securely connected with the
washers and lock washers properly in place and tighten to 175 inch-lbs, 14 ft-lbs or 20Nm
at both ends to prevent them from coming loose.
g. Connect the negative (-) black lamp lead to the negative (-) igniter terminal, left terminal. Connect the
positive (+) red lamp lead to the positive (+) igniter terminal, right terminal. CAUTION! When tight-
ening the positive and negative leads, do not tighten to the point that the brackets start to bend. Use an
adjustable wrench to support the brackets when tightening.
h. Tighten the strain reliefs.
i. Replace the igniter safety cage.
3. Move the AC Input Line Voltage switch in the upper-left corner of the LPS to the left if you are using a 200
VAC supply, or right if you are using a 400 VAC supply.
4. Use an AC Input Terminal Block that is correct for your region to connect the AC directly to the LPS.
CAUTION!
ensure adequate environmental sealing and to prevent the cable from accidentally being torn out.
• For North America, Japan and most of Central/South America (
Wire Phase 1, 2, 3 and Ground
• For Europe, (380-415 VAC):
Wire Phase 1, 2, 3, Neutral and Ground
CP4230 Setup Guide
020-100669-03 Rev. 1 (05-2014)
When connecting the high current lamp leads between the LPS and the
Use an appropriately sized strain relief connector with the knockout plate provided to
Section 2: Installation and Setup
190-208 VAC):
2-19