Pressure Seal Group PS 100 Operator's Manual page 40

Folder and sealer
Table of Contents

Advertisement

PS 300
Condition
Documents are
mishandled in the folder
or damaged during
sealing.
Documents not sealing.
Documents are
misfeeding.
14-11-02 Iss. 1.
Possible Cause
Dirty folding rollers.
Folding roller adjusted
improperly or worn; sealing
rollers adjusted improperly.
Pressure on sealing rollers
is relieved.
Documents are older than
their shelf life (one year).
Fold plate document
stop(s) adjusted improperly
causing poor registration of
adhesive strips.
Sealing rollers adjusted
improperly.
Feed table document
guides are set too tight.
Debris in folding plates;
folding plates not installed
properly; fold plate
document stop(s) adjusted
improperly.
Worn feed roll.
5. Operation Errors
Corrective Action
Clean rollers with cleaning
solution.
Contact your Pressure
Seal distributor for advice.
Reset pressure on the
sealing rollers (p.27).
Use fresh documents.
Check and adjust position
of the fold plate document
stop(s) (p.14).
Contact your Pressure
Seal distributor for advice.
Set the guides so there is
just enough clearance to
allow the document to
move freely between the
guides (p. 16).
Remove debris; properly
install folding plates;
check and adjust the
position of the fold plate
document stop(s).
Contact your Pressure
Seal distributor for advice.
Page 33