5.5.4 I/O Control

The I/O Control setup menu is used to define the settings for controlling the IP decoder
through RS-485 / RS-232 communication protocol and for IP decoder to control the
connected PTZ cameras. Please note that the RS-232 port on the IP decoder is currently
reserved.
RS-485
PTZ Protocol: Select PTZ protocol, choose from the following protocols: Transparent,
Pelco_D, Pelco_P, Everfocus or Samsung. (Note: All cameras on the RS-485 bus must use
the same protocol)
485 ID: This is the ID used by the EKB500 to send commands to the IP decoder. On an
RS-485 connection, every device (PTZ, IP decoder and controller) must be assigned an
unique ID number between 0 and 127.
Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS-485 port on the IP decoder. There are eight different speeds:
1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200
BPS.