Extractor /Tracker Settings - Simrad Maris ECDIS900 Technical Manual

Hide thumbs Also See for Maris ECDIS900:
Table of Contents

Advertisement

Extractor/Tracker Settings
Depth emulation allows Sensor Monitor to emulate depth below keel and surface using
given offsets in case if there is only depth below transducer.
Immediate data forward sets up special quick data transmission protocol that is used for
PC Radar Kit and for some OEM solutions. Activate it only when it is really needed (i.e. PC
Radar Kit presents) as it loads LAN traffic. You also can force it to be local only.
Bind unspecified ports sets up how to assign "implicit" (unspecified) UDP ports to avoid
collision with other software.
Transmitter bind address and receiver bind address (when specified) allows using the
only LAN interface card for the computer that has more than one. If these fields are
empty, the transmitter and/or receiver will use all LAN cards instead.
Parameter filtering button enters into parameter filtering setup dialog (see above)
Parameter substitution button enters into parameter substitution setup dialog (see
above)
Master Mode button switches Sensor Monitor from Master mode to Slave mode and
back. This affects immediately ECDIS900.ini file so if ECDIS is running it will be also
switched from Monitoring mode to Planning mode and back.
When the Simrad MK6.0 radar interface box is used, Sensor Monitor MASTER is in
charge of sending appropriate data to the extractor/Tracker application responsible for
radar video delivery.
It collects all information related to Extractor Tracker from other Sensor Monitor applications
running on the LAN and sends the appropriate data to the Extractor Tracker board. For
instance
The Gyro source is the most important and must be selected as follow: If one Gyro is
connected to the Planning station and another Gyro to the Monitoring station, the user has to
select which gyro data is used by the Extractor Tracker software. On the Master ECDIS
workstation it is necessary to select the source of data for E/T as follow:
Menu Option, item Settings panel Extractor / Tracker settings.
Select the sensor that provided the data parameter you want E/T Data Source.
Expand it if did not expanded already.
Select the parameter to be selected as E/T Data Source.
Check on E/T Data Source check box.