Simrad Maris ECDIS900 Technical Manual page 36

Hide thumbs Also See for Maris ECDIS900:
Table of Contents

Advertisement

Autopilot
Output mask ON specifies which relays have to be shorted when Sensor Monitor is
informed of unacknowledged alarms. This value is a mask where bit 0 represents relay
№1, bit 1 represents relay №2 , etc. Value 63 means that all 6 output relays have to be
shorted.
Output mask OFF specifies which relays have to be shorted when Sensor Monitor is
informed that there is no unacknowledged alarm.
Output mask ACK specifies which relays have to be shorted when Sensor Monitor is
informed that user has pressed acknowledge button.
Output mask DEADMAN specifies which relays have to be shorted when Sensor Monitor
is informed that nobody from the watch has touched any button of the navigational
computer for some certain time.
Time between data portions specifies how often sensor should send control signals to
the PLC.
Keep ACK mask specifies how long Sensor Monitor should keep ACK state. After this time
PLC will be reverted to OFF state.
Catch alarm from specifies from which software must Sensor Monitor receive and take
into account alarm state. Alarm state received from other software will be ignored. If the
user chooses "any sender" Sensor Monitor will accept any alarm state.