3.4.7 Fence Installation

Fit the fence rest (H, Fig.17) to the work table (B, Fig.17) and
place the spacers in between.
Tighten the nuts (Q, Fig.17) with flat & spring washers inbetween.
Manually tighten nuts (S, Fig.17) against the supplementary table (A, Fig.17)
and finally tighten nuts (Q, Fig.17).
Check linearity of the guide (H, Fig.17) and adjust, if necessary, by acting on
the nuts (S, Fig.17) (See section 4.4 rip fence adjustment) (See page 16).
Saw guide assembly with micrometric adjustment:
Fit the tubular section (P, Fig.18) and perform a test cut to check that the panel
width corresponds to the reading on the plate (R,Fig.18). If necessary, adjust
the position by loosening the fastening screws and repositioning the tubular
section (P, Fig.18).
Parallel adjustment of aluminum fence:
Loosen the Nylon nut (S, Fig. 18) and turn the set screw (T, Fig. 18)
adjust the aluminium fence parallel with the table surface.
3.5. Dust Extraction
CAUTION
Always work with the dust extraction system on. Always start the extraction
system and the motor at the same time.
Suitable extraction eliminates the risks of dust inhalation and aids better
functioning of the machine. Make sure the extraction system air flow rate is at
least 900 cu.m/hour at a speed of 25÷30 m/s.
• Connect a hose, ø 100 mm, to coupling (A, Fig.19) and a hose
to coupling (B, Fig.19), as shown in the figure 20 and
clamp.
CAUTION
The extraction pipe fitting should not hinder the operator during use of the
machine.
Fig.17
to
Fig.18
ø 30 mm
tighten through a
P
R
Fig.19
S
T
B