If you wish to distribute the load to multiple channels, it is
recommended to set the current limit of the channel that
is to supply the main current to a fraction of the current.
This approach handles the semiconductor with care and
improves the heat dissipation, as the power loss is distrib-
uted more evenly.
40

8 Specifications

Programmable power supplies 2 / 3 / 4 channels
HMP2020 HMP2030 HMP4030 HMP4040
All data valid at 23°C after 30 minute warm-up.
Outputs
Advanced parallel and series operation: simultaneous switching on/off of
active channels via "output" button, common voltage- and current control
using tracking mode (individual channel linking), individual mapping of
channels which shall be affected by FuseLink overcurrent protection
(switch-off), all channels galvanically isolated from each other and the
protective earth
HMP4040:
4 x 0 - 32 V / 0 - 10 A
HMP4030:
3 x 0 - 32 V / 0 - 10 A
HMP2030:
3 x 0 - 32 V / 0 - 5 A
HMP2020:
1 x 0 - 32 V / 0 - 10 A; 1 x 0 - 32 V / 0 - 5 A
Output terminals:
4 mm safety sockets frontside, screw-type
terminal rear side (4 units per channel)
Output power:
188 W max.
HMP4030 / HMP4040
384 W max.
HMP2020 / HMP2030
188 W max.
Compensation of lead
resistances (Sense):
1 V
Overvoltage/overcurrent
protection (OVP/OCP):
Adjustable for each channel
Adjustable for each channel,
Electronic fuse:
may be combined using FuseLink
Response time:
<10 ms
32 V channels
Output values:
HMP4040:
4 x 0 - 32 V/0 - 10 A, (5 A bei 32 V, 160 W max.)
HMP4030:
3 x 0 - 32 V/0 - 10 A, (5 A bei 32 V, 160 W max.)
HMP2030:
3 x 0 - 32 V/0 - 5 A, (2,5 A bei 32 V, 80 W max.)
HMP2020
10 A:
1 x 0 - 32 V/0 - 10 A, (5 A bei 32 V, 160 W max.)
5 A:
1 x 0 - 32 V/0 - 5 A, (2,5 A bei 32 V, 80 W max.)
Resolution:
Voltage
1 mV
Current
HMP4030 / HMP4040
<1 A: 0.2 mA; ≥1 A: 1 mA
HMP2030
<1 A: 0,1 mA; ≥1 A: 1 mA
HMP2020
10 A:
<1 A: 0,2 mA; ≥1 A: 1 mA
5 A:
<1 A: 0,1 mA; ≥1 A: 1 mA
Setting accuracy:
Voltage:
<0.05 % + 5 mV (typ. ±2 mV)
Current
HMP4030 / HMP4040
<0.1 % + 5 mA (typ. ±1 mA at I <500 mA)
HMP2030
<0.1 % + 5 mA (typ. ±0.5 mA bei I <500 mA)
HMP2020
10 A:
<0,1 % + 5 mA (typ. ±1 mA bei I <500 mA)
5 A:
<0,1 % + 5 mA (typ. ±0,5 mA bei I <500 mA)
Measurement accuracy:
Voltage:
<0.05 % + 2 mV
Current
HMP4030 / HMP4040:
<500mA: <0.05 % + 0.5 mA, typ. ±0.5 mA
≥500 mA: <0.05 % + 2 mA, typ. ±2 mA
HMP2030:
<500 mA: <0.05 % + 0.5 mA, typ. ±0.2 mA
≥500 mA: <0.05 % + 2 mA, typ. ±1 mA