Ventilation System

The ventilation system of the S5810 series consists of the air vents at both sides of the chassis, the
turbo fan, and the power module fans. With the ventilation system, the heat generated from the chassis
and the power modules can be dissipated in time to ensure the system stability. When installing the
S5810 series, select a proper location according to the ventilation design of your installation
environment.
The ventilation process of the S5810 series is shown in
both sides of the chassis, takes the heat generated from the chassis and the power modules, and then
goes out from the exhaust vents of the turbo fan and power modules. The chassis and power modules
use separate air channels for heat dissipation. Make sure that both air channels are free of obstruction.
Figure 1-10 Ventilation process of the S5810 series
(2)
(1) Front panel
(3) Air exhaust vent of the turbo fan
The turbo fan model supported by the S5810 series is LSWM1BFAN. The specifications of
LSWM1BFAN are illustrated in
Item
(3)
(1)
Table
1-20.
Specifications
300 W
Figure
(4)
(2) Air vents at both side of the chassis
(4) Air exhaust vents of the power modules
1-15
1-10. Air goes in from the air vents at