Rear Panel; Power Supply System; Ventilation System - H3C S3600 Series Installation Manual

Epon olt switches
Hide thumbs Also See for S3600 Series:
Table of Contents

Advertisement

Table 1-7 Console port specifications
Item
Connector type
Compliant standard
Transmission baud
rate
Service

Rear panel

S3600-2P-OLT rear panel
Figure 1-2 S3600-2P-OLT rear panel
(1) Grounding screw
S3600-2P-OLT-DC rear panel
Figure 1-3 S3600-2P-OLT-DC rear panel
(1) Grounding screw

Power Supply System

S3600-2P-OLT AC input voltage
Rated voltage: 100 VAC to 240 VAC, 50/60 Hz
Max voltage: 90 VAC to 264 VAC, 50/60 Hz
S3600-2P-OLT-DC DC input voltage
Rated voltage: –48 VDC to –60 VDC
Max voltage: –36 VDC to –72 VDC

Ventilation System

The S3600-2P-OLT/S3600-2P-OLT-DC provides one fan for heat dissipation of the whole system.
RJ-45
EIA/TIA-232
9600 bps to 115200 bps (defaulting to 9600 bps)
It can be connected to an ASCII terminal.
It can be connected to a serial port of a local or remote (through a pair of
modems) PC running terminal emulation program.
1-5
Specification
(2) AC receptacle
(2) DC receptacle