H3C S5810 Series Ethernet Switches

Quick Start

Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: 6PW102-20101105

Advertisement

Table of Contents
loading

Summary of Contents for H3C S5810 Series

  • Page 1: Quick Start

    H3C S5810 Series Ethernet Switches Quick Start Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: 6PW102-20101105...
  • Page 2 SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V G, V G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners.
  • Page 3: About This Manual

    About This Manual Organization H3C S5810 Series Ethernet Switches Quick Start is organized as follows: Chapter Contents Briefly introduces the appearance, system description, as well as 1 Product Overview the features and applications of the H3C S5810 series switches. Describes the requirements on installation site, the safety...
  • Page 4 Manual LSWM1BFAN fan modules. Obtaining Documentation You can access the most up-to-date H3C product documentation on the World Wide Web at this URL: http://www.h3c.com. The following are the columns from which you can obtain different categories of product documentation: [Products & Solutions]: Provides information about products and technologies, as well as solutions.
  • Page 5: Table Of Contents

    Table of Contents 1 Product Overview ······································································································································1-1 Overview ·················································································································································1-1 S5810-50S ··············································································································································1-2 Front Panel ······································································································································1-2 Rear Panel·······································································································································1-4 S5810-50S-DC········································································································································1-4 Front Panel ······································································································································1-4 Rear Panel·······································································································································1-5 Ports ························································································································································1-5 Console Port····································································································································1-5 Management Ethernet Port ·············································································································1-6 USB Interface ··································································································································1-6 10/100/1000Base-T Ethernet Port···································································································1-6 100/1000Base-X SFP Interface·······································································································1-6 SFP+ Interface·································································································································1-8 LEDs························································································································································1-9 System LED···································································································································1-10 Power Module Status LEDs ··········································································································1-10...
  • Page 6 Installing a Power Module·······················································································································3-6 Verifying the Installation ··························································································································3-6 4 Initial Power-On ·········································································································································4-1 Setting Up the Configuration Environment······························································································4-1 Connecting the Console Cable ···············································································································4-1 Console Cable ·································································································································4-1 Connection Procedure·····················································································································4-1 Setting Terminal Parameters ··················································································································4-2 Booting the Switch ··································································································································4-5 Checking before Power-On ·············································································································4-5 Powering On the Switch ··················································································································4-5 Changing the Boot Mode·················································································································4-8 5 Maintenance and Troubleshooting ··········································································································5-1 Software Loading Failure ························································································································5-1...
  • Page 7: Product Overview

    The dual power module slot design enhances the device availability, making the device applicable to the Top of Rack application at data centers. The H3C S5810 series includes the following two models, and has the system specifications as shown in Table 1-1.
  • Page 8: S5810-50S

    The S5810-50S and S5810-50S-DC switches are similar in system specifications except that they provide different power modules when shipped. S5810-50S Front Panel Figure 1-1 S5810-50S front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T auto-sensing Ethernet port status LED (3) 100/1000Base-X SFP interface status LED (4) SFP+ interface status LED (5) System LED (SYS) (6) Power module 1 status LED (PWR1)
  • Page 9 Figure 1-3 Logo panel of the S5810 series I To pull out and push in the logo panel, follow these steps: Use your fingertip to hold the arc notch at the right edge of the logo panel, and then pull the panel out with appropriate strength.
  • Page 10: Rear Panel

    You can select two power modules to implement 1+1 power supply redundancy. See Pluggable Power Modules on page 1-13 for the power module models supported by the S5810 series. See H3C PSR300-12A & PSR300-12D1 Power Modules User Manual for the detailed description of the power modules.
  • Page 11: Rear Panel

    S5810 series. See H3C PSR300-12A & PSR300-12D1 Power Module User Manual for the detailed description of the power modules. Ports Console Port Each S5810 series provides one console port on the front panel. Table 1-2 describes the console port specifications. Table 1-2 Console port specifications Item...
  • Page 12: Management Ethernet Port

    Management Ethernet Port The S5810 series provides a management Ethernet port, which connects to a computer to perform system program loading and debugging without being affected by the switching chip working status; or the management Ethernet port can be connected to a remote NMS to implement remote management of the system.
  • Page 13 Table 1-5 Combo port groups of the S5810 series Combo port group SFP interface number Ethernet port number Table 1-6 describes the 100/1000Base-X SFP interface specifications. Table 1-6 S5810 series 100/1000Base-X SFP interface specifications Item Specification LC (for SFP optical interface module)/RJ-45 (for SFP electrical interface...
  • Page 14: Sfp+ Interface

    The types of SFP optical modules may update with time. For information about SFP modules, contact technical support. For the models and specifications of each kind of optical modules, refer to H3C Low End Series Ethernet Switches Pluggable Modules Manual.
  • Page 15: Leds

    You are recommended to use SFP+ transceivers of H3C on the S5810 series. The types of SFP+ transceivers may update with time. For information about transceivers, contact technical support. For the models and specifications of each kind of transceivers, refer to H3C Low End Series Ethernet Switches Pluggable Modules Manual. LEDs...
  • Page 16: System Led

    Description SFP+ interface status LED See SFP+ Interface Status LED on page 1-13. See Management Ethernet Port Status LED on page Management Ethernet port status LED 1-13. System LED Table 1-10 System LED description Status Description Steady green The switch is started normally. Flashing green (1 Hz) The system is performing POST.
  • Page 17: Port Mode Led

    Status Mark Description System LED Seven-segment LED status (SYS) status numbers one by one. displays the POST test ID. The LED flashes the specific POST failed. The LED flashes numbers. Flashing red the POST test ID of the failed test. A bar rotates clockwise around the LED.
  • Page 18: 100/1000Base-X Sfp Interface Status Led

    Table 1-14 10/100/1000Base-T auto-sensing Ethernet port LEDs description Status Meaning Port mode Ethernet port status LED The port operates at the rate of 1000 Mbps; the LED is fast Steady green flashing when data is being sent and/or received on the port.
  • Page 19: Sfp+ Interface Status Led

    Pluggable Power Modules The S5810 series provides two power module slots. A power module is shipped with the switch. A PSR300-12A AC power module is shipped with the S5810-50S A PSR300-12D1 DC power module is shipped with the S5810-50S-DC The switch only requires one power module to ensure the normal operation of the whole system.
  • Page 20: Ac Power Module

    Ventilation System The ventilation system of the S5810 series consists of the air vents at both sides of the chassis, the turbo fan, and the power module fans. With the ventilation system, the heat generated from the chassis and the power modules can be dissipated in time to ensure the system stability.
  • Page 21 S5810 series, select a proper location according to the ventilation design of your installation environment. The ventilation process of the S5810 series is shown in Figure 1-10. Air goes in from the air vents at both sides of the chassis, takes the heat generated from the chassis and the power modules, and then goes out from the exhaust vents of the turbo fan and power modules.
  • Page 22 LED (for details, refer to Table 1-12). If a failure occurs, replace the turbo fan in time (for how to replace a turbo fan, refer to Fan Tray Failure). For detailed information about fan trays, refer to H3C LSWM1FAN & LSWM1BFAN Installation Manual. 1-16...
  • Page 23: Installation Preparations

    When replacing hot-swappable power modules and fan trays, wear ESD-preventive gloves to avoid damaging the units. Installation Site The S5810 series must be used indoors. You can mount the switch in a rack or on a workbench, but make sure: Adequate clearance is reserved at the air inlet/exhaust vents for ventilation.
  • Page 24: Cleanness

    Use electromagnetic shielding, for example, shielded interface cables, when necessary. Route interface cables only indoors to prevent signal ports from getting damaged by over-voltage or over-current caused by lightning strikes. Laser Safety The S5810 series are Class 1 laser devices.
  • Page 25: Installation Tools

    When an optional interface module or SFP/SFP+ module on the S5810 series is operating, do not stare into the optical port because the laser light emitted from the optical fiber may hurt your eyes. Installation Tools Flat-blade screwdriver Phillips screwdriver ESD-preventive wrist strap The installation tools are not shipped with the S5810 series.
  • Page 26: Installing A Switch

    Installing a Switch On a mounting screw of the chassis of the H3C series switches, there is a seal labeled with H3C. You must keep it intact before asking the agent to maintain the switch. You must get the permission of the local agent before you can open the chassis.
  • Page 27: Mounting The Switch To A Rack

    and rear mounting (because the installation procedures of the two brackets are the same, each figure shows only how to install one bracket). Fasten the M4x8 screws. Figure 3-3 Attach the mounting bracket to an S5810 for front mounting Figure 3-4 Attach the mounting bracket to an S5810 for center mounting Figure 3-5 Attach the mounting bracket to an S5810 for rear mounting Mounting the Switch to a Rack Wear an ESD-preventive wrist strap and make sure the rack is well grounded and is firm enough to...
  • Page 28: Mounting The Switch On A Workbench

    If support trays are provided on the rack, you can mount the switch to the rack with mounting brackets and trays. Put the switch on the support tray and slide the switch to an appropriate place. Then fix the mounting brackets. Figure 3-6 Mount the S5810 to a rack Mounting the Switch on a Workbench In many cases, standard 19-inch cabinets are not available.
  • Page 29: Connecting The Ground Wire

    Place the switch with bottom up carefully, and then clean the round holes on the chassis bottom with dry cloth. Attach the rubber feet to the four round holes on the chassis bottom. Place the switch with upside up on the workbench. During the operation, you simply need to: Make sure that the workbench is flat and sturdy.
  • Page 30 Figure 3-7 Connect the PGND cable to the grounding hole of switch (1) Rear panel of the switch (2) Grounding sign (3) Grounding hole (4) OT terminal (5) PGND cable (6) Grounding screw To attach the other end of the PGND cable to the grounding strip in the equipment room, follow these steps: Cut the PGND cable to a proper length according to the distance between the switch and the grounding strip.
  • Page 31: Installing A Power Module

    Installing a Power Module The S5810 series provides two power module slots on its rear panel. Hot swappable power module slot 1 is empty when the switch is shipped, and hot swappable power module 2 is installed with a filler panel.
  • Page 32: Initial Power

    Initial Power-On Setting Up the Configuration Environment Set up the configuration environment as follows: Connect a terminal (a PC in this example) to the console port on the switch with a console cable. Figure 4-1 Network diagram for configuration environment setup Connecting the Console Cable Console Cable A console cable is an 8-core cable.
  • Page 33: Setting Terminal Parameters

    Plug the DB-9 female connector of the console cable to the serial port of the PC or terminal where the switch is to be configured. Connect the RJ-45 connector of the console cable to the console port of the switch. Pay attention to the mark on the console port and be sure to plug the connector to the right port.
  • Page 34 Figure 4-3 Connection description of HyperTerminal Type the name of the new connection in the connection description interface and click OK. The following interface pops up. Select the serial port to be used from the Connect using drop-down list. Figure 4-4 Set the serial port used by the HyperTerminal connection Click OK after selecting a serial port and the following interface pops up.
  • Page 35 Figure 4-5 Set the serial port parameters Click OK after setting the serial port parameters and the system enters the following interface. Figure 4-6 HyperTerminal window Click Properties in the HyperTerminal window to enter the properties window. Click Settings to enter the following properties setting window, set the emulation to VT100, and then click OK.
  • Page 36: Booting The Switch

    The console cable is properly connected; the terminal (which can be a PC) used for configuration has been started; and the configuration parameters have been set. Powering On the Switch The S5810 series have the same Boot ROM display style. This document uses the Boot ROM display of S5810-50S as an example: Starting..
  • Page 37 Memory Size : 512MB Flash Size : 256MB CPLD Version : 000 PCB Version : Ver.A Mac Address : 00E0FC005810 Press Ctrl-B to enter Extended Boot menu...1 The last line asks whether you want to enter the Boot Menu. The system waits one second for your response.
  • Page 38 You can configure the switch now. The H3C Series switches provide abundant command views. For detailed descriptions about the configuration commands and CLI, refer to H3C S5810 Series Ethernet Switches Operation Manual and H3C S5810 Series Ethernet Switches Command Manual.
  • Page 39: Changing The Boot Mode

    9. Set switch startup mode 0. Reboot Enter your choice(0-9): Select 0. The system reboots in normal startup mode and displays the following information: Starting..************************************************************************ H3C S5810-50S BOOTROM, Version 103 ************************************************************************ Copyright (c) 2004-2008 Hangzhou H3C Technologies Co., Ltd.
  • Page 40 You can configure the switch now. The H3C Series switches provide abundant command views. For detailed descriptions about the configuration commands and CLI, refer to H3C S5810 Series Ethernet Switches Operation Manual and H3C S5810 Series Ethernet Switches Command Manual.
  • Page 41: Maintenance And Troubleshooting

    Maintenance and Troubleshooting Software Loading Failure If software loading fails, the system runs steadily using the original system file. In this case, check whether the physical ports are properly connected. If not, reconnect them correctly and restart the loading procedure. If so, view the loading procedure information displayed on the HyperTerminal to check for input errors.
  • Page 42: Power Supply Failure

    Only when the system LED and the seven-segment LED are displayed as steady red and F respectively does it indicate that a fan tray fails. To replace the fan tray, refer to H3C S5810 Series Ethernet Switches Installation Manual for detailed operation steps.
  • Page 43 Troubleshooting when the terminal display is illegible If there is illegible display at the configuration terminal, the cause might lie in the parameter setting error at the terminal (such as HyperTerminal). Verify the following terminal parameter (such as hyper terminal) settings: Baud rate: 9,600 Data bits: 8...
  • Page 44 Table of Contents Appendix A Lightning Protection of the Switch······················································································· A-1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) ······················ A-1 Installation of Lightning Arrester for Network Port ················································································· A-2 Appendix B Compliance and Safety Manual ···························································································· B-1 Regulatory compliance standards··········································································································...
  • Page 45: Appendix A Lightning Protection Of The Switch

    Appendix A Lightning Protection of the Switch Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed. If an outdoor AC power cord should be directly led to the switch, please serially connect the lightning arrester for AC power (Socket Strip with Lightning Protection) before you plug AC power cord into the switch, thus to prevent the possible damage to the switch due to lightning strike.
  • Page 46: Installation Of Lightning Arrester For Network Port

    Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
  • Page 47 Step 2: According to the distance to the grounding screw of the switch, cut the ground wire of the arrester, and securely tightening its ground wire to the grounding screw of the switch. Step 3: Use the multimeter to measure whether the ground wire of the arrester contacts well with the grounding screw of chassis.
  • Page 48: Appendix B Compliance And Safety Manual

    FDA 21 CFR Subchapter J GB 4943 European Directives compliance LVD/EMC Directive H3C S5810-50S product complies with the European Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC. A copy of the signed Declaration of Conformity can be downloaded from: http://www.h3c.com/portal/Technical_Documents...
  • Page 49: Usa Regulatory Compliance

    Directive and must be disposed of in a responsible manner. USA regulatory compliance FCC Part 15 H3C S5810-50S complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference.
  • Page 50: Japan Regulatory Compliance

    CISPR 22 compliance H3C S5810-50S complies with the requirements of CISPR 22 for Class A Information Technology Equipment (ITE). Warning: If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
  • Page 51 Before any operation is performed, please read the operation instructions and precautions carefully to minimize the possibility of accidents. The Note, Caution, Warning and Danger items in other manuals do not cover all safety precautions that should be followed. They are only the supplements to the safety precautions for operations as a whole.
  • Page 52 为了避免可能发生的事故, 请在进行任何操作前, 仔细阅读设备操作手册和本章节的安全规范。 手册中 出 现的说明、注意、警告、危险,不能涵盖所有的安全预防,仅仅是在整个操作过程中的安全提示和补充。 因此,负责安装和日常维护本设备的人员必须具备安全操作基本技能。 操作人员要按照当地的安全规范进行操作。出现在产品手册中的安全预防措施仅仅是当地安全规范的补 充。 在操作本设备时,请认真执行产品手册规定的安全规范。 设备安装、维护人员必须通过专业培训,并且掌握足够的操作技能和安规预防意识。只有专业人员才能 担任本设备的安装和维护工作。 Conventions Used Symbole Erläuterung 应用惯例 The symbols in this manual are shown in the following table. They are used to remind the reader of the safety precautions during equipment installation and maintenance. Die Symbole in diesem Handbuch verwendeten sind in der folgenden Tabelle dargestellt.
  • Page 53 Read all the instructions before operation. Lesen Sie alle Anweisungen sorgfältig durch, bevor Sie mit dem Arbeiten beginnen. 在进行操作前仔细阅读手册内容。 When installing the unit, always make the ground connection first and disconnect it last. Beachten Sie, dass bei der Installation des Systems stets zuerst die Erdverbindung angebracht wird und das die Erdverbindung stets als letztes getrennt wird.
  • Page 54: Electricity Safety Elektrische Sicherheit 用电安全

    AC 供电:插座必须随时可用,因为它是主要的切断电源装置。 Because the device has several power supplies, disconnect all of them to switch off the device. Da das Gerät mehrere Energiequellen hat, ist es notwendig stets alle Verbindungen zu unterbrechen, um den energiefreien Zustand zu erreichen. 因为设备存在多种电源输入,在关闭设备时确保切断所有电源连接。 To prevent laser radiation from hurting your eyes, never stare into the open optical port. Nehmen Sie das Gerät nicht in Betrieb, solange das optische Fenster nicht geschlossen ist.
  • Page 55 When water is found in the rack, or the rack is damp, please immediately switch off the power supply. Sollte sich Wasser im Baugruppenträger befinden oder der Baugruppenträger feucht sein, ist die Energiezufuhr sofort zu unterbrechen und das System abzuschalten. 当有液体进入机架或机架有损坏时,请立即切断电源。...
  • Page 56 Das Entfernen und Anbringen von Zuleitungen ist strengstens verboten. Kurzschlüsse zwischen innerem und äußerem Leiter können Lichtbögen oder Funkenflug verursachen, was zu Feuer oder einer Augenverletzung führen kann. 禁止安装和移动带电的线缆。因为导电体和带电的线缆,即使短暂接触,也会引起电火花或电弧,从而 导致失火或是伤害眼睛。 Before the power cable is installed or removed, the power switch must be turned off. Das System muss stets abgeschaltet werden, bevor die Zuleitung angebracht oder entfernt wird.
  • Page 57: Laser Laser激光辐射

    Thunderstorm Gewitter 防雷击 High voltage and AC operations or operations on a steel tower and a mast on a thunderstorm day are prohibited. In order to prevent the equipment from being damaged by lightning, proper grounding is required. Arbeiten mit Hochspannung und Wechselstrom oder Arbeiten auf Stahltürmen und masten während eines Gewitters sind verboten.