7. Make sure the drain valve is fully closed.
Turn the fryer ON and allow the cooking
oil/shortening to reach setpoint.
NOTE: Ensure the fryer drain valve is fully
closed before turning the fryer on. If the drain
valve is not fully closed, the controller will
display an error message or a trouble light and
fryer will not operate.
CHANGING THE FILTER PAPER
DANGER
Allow the filter pan to cool completely
before attempting to change the paper.
1. Slide the filter unit from the cabinet.
2. Remove and clean the crumb tray.
47 SERIES GAS FRYERS
CHAPTER 4: FILTRATION INSTRUCTIONS
3. Remove the hold-down ring from the filter
pan and clean.
4. Remove and discard the used filter paper.
5. Remove the metal filter screen and clean
thoroughly using a solution of hot water
and detergent. Allow the screen to dry
completely before reinstalling.
4-5