Immediately after each use, drain the Power
Shower completely. If you suspect blockage,
unscrew the clean-out plugs at each corner of
the frame. Place the frame in a pan of hot
water for several minutes to melt any
accumulation of solidified oil/shortening. Use
a long, narrow bottlebrush with hot water and
detergent to clean inside the tubes.
necessary, insert a straightened paper clip or
similar instrument into the holes in the frame
47 SERIES GAS FRYERS
CHAPTER 5: PREVENTIVE MAINTENANCE
If
to remove any blockages.
thoroughly, and reinstall the plugs before
using.
Failure to reinstall the clean-out plugs
will cause hot oil/shortening to spray
out of the frypot during the filtering
process, creating an extreme burn
hazard to personnel.