(31) TP4 (frequency control)
PCBA Interface Control
Test point for measuring the frequency control signal within the read
data separator.
TP4 is used to adjust the VFO operating point.
TP4 -
-----------
----- ---- 2.5 V
Fig. 353
Example of waveform at TP4
(32) TP5 (read data pulse R)
PCBA Interface Control
Test point for measuring the read data pulse R signal.
TP5 is used to check the operation of the write/read system.
J4-17
RD
signal
~
TP5
J4-17
RD
signal
.-J
TP5
t
t
560 ns (Write operation)
440 ns (Read operation)
(a) "90 ips"
llions
.
,
(b) "30
ips"
Fig. 354
Example of waveform at TP5
- 373 -