Fig. 332 Tape Position Management - Teac MT-20D-IO Maintenance Manual

Streaming cassette magneteic tape unit
Table of Contents

Advertisement

(3)
Tape position manangement
The TAPE POSITION MANAGEMENT CIRCUIT is a circuit to convert hole
information from the DRIVE IfF into tape position code.
This circuit
becomes operable after initialization has been completed.
After Power ON
(with the cassette loaded).
cassette loading,
or
resetting. this circuit is inhibited by the PRDY signal until the EOT
or BOT side clear leader is detected.
After the EOT or BOT side clear leader is detected and the tape
position is initialized
(each signal of UTHI and LTHI is set to
either EOT position or BOT position status),
the inhibit of this
circuit
is
released.
Then,
this
circuit
is
placed
in operable
status.
FWDD
HOL(H)
I
---------
..
TAPE POSITION
I
MANAGEMENT
t
I
HOLE
I
CLOCKING
-----------~
TAPE POSITION MANAGEMENT
CIRCUIT
,
,
I
I
I
I
I
I
RST
PRDY eLK
Fig. 332
Tape position management
- 356 -
UTa
LTH
HOLD