Teac MT-20D-IO Maintenance Manual page 136

Streaming cassette magneteic tape unit
Table of Contents

Advertisement

(b)
8
Key in "F" to stop the operation.
9
Key
in
"A2l",
and
further
"I",
and
adjust
the
variable
resistor
R17
(Fig.
336)
until the burst signal VI is within
1.3
to 2 Vpp (Fig. 42S).
. r - - - '
,--I
I
I
I
I
Vi
V2
V3
va
V5
v6lv7}--
I
I
I
Vi
V2
V 3 1 - - - - - -
I
I
I
L.---"l.. _ _
~
(i) Track
0
(ii) Track 1,2
Note
Fig. 42S
Burst signal
Be
careful
since
the
measuring
range
of
the
alignment
becomes narrower, if VI does not reach
1.3
V according to
the characteristics of the head and alignment tape.
Check for the head alignment in the following procedure:
1
Key in "0" or "1" to wind the tape nearly to the winding
center, and then key in "F".
2
Key in "A20" .
3
Key in "BS", and read the DATA on display of track
O.
Display DATA 2
Off track
1 +.\
I
(mm)
4
Key in "A2l".
S
Key in "BS", and read the DATA on display of track 1.
Display DATA 1
Azimuth
1+1
.1
I
(MINT)
Display DATA 2
Off track
I +
J
I I
(nun)
6
Key in "A22".
7
Key in "BS" • and read the DATA on display of track 2.
Display DATA 1
Azimuth
1+1
.1
(MINT)
Display DATA 2
Off track
I +.1
I
(nun)
- 4043 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mt-2st

Table of Contents