Adjusting Fan Belt Tension; Checking Fuel Line - Kubota M100GX Operator's Manual

Hide thumbs Also See for M100GX:
Table of Contents

Advertisement

114
PERIODIC SERVICE
A The air cleaner uses a dry element, never apply oil.
A Do not run the engine with filter element removed.
A Be sure to refit the cover with the arrow
of cover) upright. If the cover is improperly fitted,
evacuator valve will not function and dust will adhere
to the element.
A Do not touch the secondary element except in cases
where replacing is required.
(See "Replacing Air Cleaner Secondary Element" in
"EVERY 1 YEAR" in "PERIODIC SERVICE" section.)
A [M126GX, M135GX]
Be sure to refit the secondary element with the arrow
upright.
C Evacuator Valve
Open the evacuator valve once a week under ordinary
conditions - or daily when used in a dusty place - to get rid
of large particles of dust and dirt.
BAdjusting Fan Belt Tension
[M100GX, M110GX]
To avoid personal injury:
A Be sure to stop the engine before checking belt
tension.
A deflection of between 7 to 9 mm
Proper fan belt
when the belt is pressed in the
tension
middle of the span.
1. Stop the engine and remove the key.
2. Apply moderate thumb pressure to belt between
pulleys.
3. If tension is incorrect, loosen the alternator mounting
bolts and, using a lever placed between the alternator
and the engine block, pull the alternator out until the
deflection of the belt falls within acceptable limits.
4. Replace fan belt if it is damaged.
(1) Bolt
(on the rear
(A) Check the belt tension
(B) To tighten
BChecking Fuel Line
1. Check to see that all lines and hose clamps are tight
and not damaged.
2. If hoses and clamps are found worn or damaged,
replace or repair them at once.
(1) Fuel lines
(2) Clamp bands
(3) Fuel cooler

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M110gxM126gxM135gx

Table of Contents