Details Of Simulation - Sharp MX-M260 Service Manual

Digital multifunctional system
Hide thumbs Also See for MX-M260:
Table of Contents

Advertisement

3. Details of simulation

1
1-1
Purpose
Operation test/check
Function
Used to check the operation of the scanner unit and its
(Purpose)
control circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/procedure
Enter the number of operations, and set the magnification ratio and the
original size.
1. Select the desired item, and press the [START] key.
2. Enter the set value with the 10-key, and press the [START] key.
The scanner unit operates at the speed corresponding to the set value.
The scan counter is displayed during execution.
25% to 400% (1% increment)
Set magnification ratio
(Default 100%)
Document size
Varies depending on the destination.
Set number of times
1 to 999 (0: Continuous operation)
1-2
Purpose
Operation test/check
Function
Used to check the operation of sensor and detector in
(Purpose)
the scanning (read) section and the related circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/procedure
The status of sensors and detectors in the scanner section is dis-
played. The active sensors and detectors are highlighted.
MHPS
Mirror home position sensor
2
2-1
Purpose
Operation test/check
Function
Used to check the operation of the RSPF unit and the
(Purpose)
related circuit.
Section
RSPF
Item
Operation
Operation/procedure
Enter the number of operations, and set the magnification ratio and the
original size.
1. Select the desired item, and press the [START] key.
2. Enter the set value with the 10-key, and press the [START] key.
The RSPF unit operates at the speed corresponding to the set value.
The scan counter is displayed during execution.
50% to 200% (1% increment)
Set magnification ratio
(Default 100%)
Document size
Varies depending on the destination.
Duplex
Selectable only when RSPF is installed.
Set number of times
1 to 999 (0: Continuous operation)
Note: Executable only when the RSPF is installed.
Purpose
Function
(Purpose)
Section
Item
Operation/procedure
The operations of sensors and detectors in the RSPF section are dis-
played.
The active sensors and detectors are highlighted.
(For the original size, the detection result of the original size displayed
on the copy menu is highlighted.)
EMPS
DLS1
DLS2
FGOD
DFD
RDD
OPCLS
SWD_LEN
SWD_A/D
RSPF width detection size (One of the following is displayed.)
A4/A3, LT/WLT, B5/B4, INV/LTR, A5/A4R, B5R, EXTRA, 8K/16K, 16KR
Note: Executable only when the RSPF is installed.
Purpose
Function
(Purpose)
Section
Item
Operation/procedure
Select the load to be checked with the 10-key, and press the [START] key.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
1 DTM-F
2 DTM-R
3 DFCL
4 CLH
5 GSOL
6 RSOL
Note: Executable only when the RSPF is installed.
MX-M260/M310/M260N/M310N SIMULATION 6 - 6
2-2
Operation test/check
Used to check the operation of sensors and detectors
in the RSPF unit and the related circuit.
RSPF
Operation
Original empty sensor
Original length sensor (Small)
Original length sensor (Large)
RSPF paper feed cover open/close sensor
RSPF paper entry sensor
RSPF original exit sensor
Book sensor
Original detection width sensor
(Unit of 0.1mm. "Width x 10" is displayed. Example: For
300mm, 3000 is displayed.)
Original detection width sensor A/D value
2-3
Operation test/check
Used to check the operation of the loads in the RSPF
unit and the control circuits.
RSPF
Operation
Item
Content
RSPF motor forward rotation
RSPF motor reverse rotation
RSPF paper feed clutch
RSPF PS clutch
Document exit gate solenoid
Document exit pressure solenoid