Sharp MX-M260 Service Manual page 44

Digital multifunctional system
Hide thumbs Also See for MX-M260:
Table of Contents

Advertisement

Output is made with the entered value for 30sec, and the display
returns to the original state.
Item
1
DENS1 (145)
Density1 (145mm/s)
2
DENS2 (145)
Density2 (145mm/s)
3
DENS3 (145)
Density3 (145mm/s)
4
DENS4 (145)
Density4 (145mm/s)
5
DENS5 (145)
Density5 (145mm/s)
6
TS (145)
Toner save (145mm/s)
7
DENS1 (122)
Density1 (122mm/s)
8
DENS2 (122)
Density2 (122mm/s)
9
DENS3 (122)
Density3 (122mm/s)
10 DENS4 (122)
Density4 (122mm/s)
11 DENS5 (122)
Density5 (122mm/s)
12 TS (122)
Toner save (122mm/s)
The minimum increment is 10V.
The result of (Set value) -200/ 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
*10+200) is used as the set value.
8-11
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the main
Function
charger grid voltage in each printer mode and the
(Purpose)
control circuit.
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Section
Photo conductor
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is highlighted.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Item
1
DENS1 (145)
Density 1 (145mm/s)
2
DENS2 (145)
Density 2 (145mm/s)
3
DENS3 (145)
Density 3 (145mm/s)
4
DENS4 (145)
Density 4 (145mm/s)
5
DENS5 (145)
Density 5 (145mm/s)
6
TS (145)
Toner save (145mm/s)
7
DENS1 (122)
Density 1 (122mm/s)
8
DENS2 (122)
Density 2 (122mm/s)
9
DENS3 (122)
Density 3 (122mm/s)
10 DENS4 (122)
Density 4 (122mm/s)
11 DENS5 (122)
Density 5 (122mm/s)
12 TS (122)
Toner save (122mm/s)
Min. unit: 10V increment
Installa
Content
tion
Default
range
300
370
420
530
600
250
200-
650
300
370
420
530
600
250
Installa
Content
tion
Default
range
440
510
560
670
740
390
350-
750
440
510
560
670
740
390
MX-M260/M310/M260N/M310N SIMULATION 6 - 11
8-13
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the
Function
developing bias voltage in FAX mode and the control
(Purpose)
circuit.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Operation/procedure
1. Enter the set value with the 10-key.
2. Press the [START] key.
Output is made with the entered value for 30sec. and the display
returns to the original state.
Setting range
200-650
Default
450
The minimum increment is 10V.
The result of (Set value-200) / 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value ∗ 10
+200) is used as the set value.
Therefore, an even number must be entered. If not, the entered odd
number +1 is displayed after pressing [START] key.
8-14
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the main
Function
charger grid voltage in FAX mode and the control
(Purpose)
circuit.
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Section
Photo conductor
Operation/procedure
1. Enter the set value with the 10-key.
2. Press the [START] key.
Output is made with the entered value for 30sec. and the display
returns to the original state.
Setting range
350-750
Default
590
9
9-1
Purpose
Operation test/check
Function
Used to check and adjust the operation of the load
(Purpose)
(motor) in the duplex section and the control circuit.
Section
Duplex
Item
Operation
Operation/procedure
1. Select the operation mode with the 10-key.
2. Press the [START] key.
The operation is performed for 30sec, and the display returns to the
original state.
Item
Duplex motor/Duplex 2 motor forward rotation
1
DMF145
(145mm/s)
Duplex motor/Duplex 2 motor forward rotation
2
DMF122
(122mm/s)
Duplex motor/Duplex 2 motor reverse rotation
3
DMR145
(145mm/s)
Duplex motor/Duplex 2 motor reverse rotation
4
DMR122
(122mm/s)
Content

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-m310Mx-m310nMx-m260n