7-8
Purpose
Setting/Operation test/check
Function
Used to set the display of the warm-up time.
(Purpose)
Item
Operation
Operation/procedure
1. Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2. The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3. After completion of warming up, "WARM UP COMPLETED" is dis-
played and the control returns to the initial screen.
8
8-1
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the
Function
developing bias voltage in each copy mode and the
(Purpose)
control circuit.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
Item
1
AE (145)
AE (145mm/s)
2
TEXT (145)
Character (145mm/s)
Character/Photo
3
TEXT/PHOTO (145)
(145mm/s)
4
PHOTO (145)
Photo (145mm/s)
5
TONER SAVE (145)
Toner save (145mm/s)
6
AE (122)
AE (122mm/s)
7
TEXT (122)
Character (122mm/s)
Character/Photo
8
TEXT/PHOTO (122)
(122mm/s)
9
PHOTO (122)
Photo (122mm/s)
10
TONER SAVE (122)
Toner save (122mm/s)
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 10V.
The result of (Set value) -200/ 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
*10+200) is used as the set value.
Setting
Content
Default
range
450
450
450
450
400
200-
650
450
450
450
450
400
MX-M260/M310/M260N/M310N SIMULATION 6 - 10
8-2
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the main
Function
charger grid voltage in each copy mode and the control
(Purpose)
circuit.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Item
1
AE (145)
AE (145mm/s)
2
TEXT (145)
Character (145mm/s)
Character/Photo
3
TEXT/PHOTO (145)
(145mm/s)
4
PHOTO (145)
Photo (145mm/s)
5
TONER SAVE (145)
Toner save (145mm/s)
6
AE (122)
AE (122mm/s)
7
TEXT (122)
Character (122mm/s)
Character/Photo
8
TEXT/PHOTO (122)
(122mm/s)
9
PHOTO (122)
Photo (122mm/s)
10 TONER SAVE (122)
Toner save (122mm/s)
Min. unit: 10V increment
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
8-10
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the
Function
developing bias voltage in each printer mode and the
(Purpose)
control circuit.
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Section
Developer/Toner hopper
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Setting
Content
Default
range
590
590
590
590
540
350-
750
590
590
590
590
540

Hide quick links: