6
6-1
Purpose
Operation test/check
Used to check the operation of the loads (clutches and
Function
solenoids) in the paper transport system and the
(Purpose)
control circuit.
Section
Paper transport (Discharge/Switchback/Transport)
Item
Operation
Operation/procedure
1. Select the load to be checked with the 10-key, and press the
[START] key.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
When the [SYSTEM SETTINGS] is pressed, the operation is interrupted.
The lift-up motor operates only when the tray is opened.
Item
1
LUM1
1st tray lift-up motor
2
CPFC1
1st tray pick-up solenoid
3
CPFS1
1st tray paper feed clutch
4
MPFS
Manual feed pick-up solenoid
5
RRC
Resist roller clutch
6
PSPS
Separation pawl solenoid
7
OGS
Paper exit gate switching solenoid
8
LUM2
2nd tray lift-up motor
9
CPFC2
2nd tray pick-up solenoid
10
CPFS2
2nd tray paper feed clutch
11
TRC2
2nd tray transport roller clutch
12
LUM3
3rd tray lift-up motor
13
CPFC3
3rd tray pick-up solenoid
14
CPFS3
3rd tray paper feed clutch
15
TRC3
3rd tray transport roller clutch
16
LUM4
4th tray lift-up motor
17
CPFC4
4th tray pick-up solenoid
18
CPFS4
4th tray paper feed clutch
19
ROGS
Right paper exit gate solenoid
The lift-up motor operates only when the tray is opened.
6-2
Purpose
Operation test/check
Function
Used to check the operation of each fan motor and its
(Purpose)
control circuit.
Section
Others
Item
Operation
Operation/procedure
Select the load to be checked with the 10-key, and press the [START] key.
The selected load is operated for 10sec.
Item
1
VFM
Fusing fan operates
Power cooling fan, power cooling fan 2
2
DCFM&DCFM2
operations
3
VFM2
Fusing exit paper fan operates
Fusing fan, power cooling fan, and
VFM&DCFM&DCFM2
3
power cooling fan 2 are operated at the
&VFM2
same time.
Content
Content
MX-M260/M310/M260N/M310N SIMULATION 6 - 9
7
7-1
Purpose
Setting/Operation test/check
Function (Purpose)
Used to set the aging operation conditions.
Item
Operation
Operation/procedure
1. Select the load to be set with the 10-key.
2. Press the [START] key.
When selected without setup, the selected value is registered and
highlighted. When selected with previous setup, the previous setup is
canceled and it is displayed normally.
Press [CA] key, and the simulation will be terminated and the machine
goes into the aging standby mode with the set content.
This setting is canceled by power OFF.
Item
1
AGING
Aging enable/disable setting
2
MISFEED
Jam detection enable/disable setting
Fusing operation enable/disable setting
3
FUSING*1
The fusing temperature is not controlled.
The heater is not turned ON.
4
INTERVL
Intermittent setting (Valid only when set to AGING.)
Warm-up save setting
The machine goes into the ready state only by
5
WARMUP
shading, disregarding fusing and process control.
After going into the ready state, normal control is
performed.
6
DV CHK.
Developing unit detection enable/disable setting
*1: When the machine exits from the fusing ignoring state, the roller may
be cooled down. Therefore, reset the machine to warm up again.
When, therefore, the simulation is canceled by pressing the [CA]
key or when the copy mode display is shifted to the initial menu dis-
play in the simulation mode of one page copy, the machine is reset.
Note: In SIM 7-1, pressing [CA] key terminates the simulation and the
machine enters the aging mode without resetting. Therefore, to
perform "4. Intermittent setup," the intermittent cycle must be set
with SIM 7-6 in advance.
Reset is not performed when the machine enters the aging mode.
7-6
Purpose
Setting/Operation test/check
Function (Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/procedure
1. Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2. Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Setting range
1-255
Default
3
Content