3. Select the soft SW reflection.
Item
1
NO STORE TO SW
Not reflected.
2
STORE TO SW
Reflected. (Shift SW value changed.)
Note: Executable only when the FAX is installed.
66-17
Purpose
Operation check/test
Function
Used to check the DTFM signal send operation.
(Purpose)
(Signal send level: Max.)
Section
FAX
Item
Operation
Operation/procedure
Enter the DTFM signal (1 digit (1 to 9, 0, *, #)) and press the [START] key.
When the [SYSTEM SETTINGS] key is pressed during execution, the
simulation is terminated.
Note: Executable only when the FAX is installed.
66-18
Purpose
Operation check/test
Function
Used to check the DTFM signal send operation.
(Purpose)
(Signal send level: Set by soft SW.)
Section
FAX
Item
Operation
Operation/Procedure
Enter the DTFM signal (1 digit (1 to 9, 0, *, #)) and press the [START] key.
When the [SYSTEM SETTINGS] key is pressed during execution, the
simulation is terminated.
Note: Executable only when the FAX is installed.
66-19
Purpose
Back up
Function
Used to write the SRAM data to the Flash ROM.
(Purpose)
Section
FAX
Item
Data
Operation/Procedure
Select "1: YES" with the 10-key, and press the [START] key. The data
are backed up. (When "2: NO" is selected, the simulation is canceled.)
* The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
cuted, data are initialized and deleted. In addition, the AR-FX7 data
cannot be used in the AR-FX5.
Note: Executable only when the FAX is installed.
66-20
Purpose
Back up
Function
Used to write the Flash ROM data to the SRAM.
(Purpose)
Section
FAX
Item
Data
Operation/Procedure
Select "1: YES" with the 10-key, and press the [START] key. The Flash
ROM data are read out and written into the SRAM. (When "2: NO" is
selected, the simulation is canceled.)
* The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
cuted, data are initialized and deleted. In addition, the AR-FX7 data
cannot be used in the AR-FX5.
Note: Executable only when the FAX is installed.
Content
MX-M260/M310/M260N/M310N SIMULATION 6 - 40
66-21
Purpose
Check
Function (Purpose)
FAX information print
Section
FAX
Item
Data
Operation/procedure
1. Select the item to be printed.
2. Press the [START] key.
The information of the selected item is printed.
Item
1
USER SW.LIST
User setting list
2
SOFT SW.LIST
Soft SW list
System error list
3
SYSTEM ERROR
Used to print the system error log (error
number and time).
Protocol error list
Regardless of soft SW38-1 status, the
protocol monitor of the preceding
communication is printed. (Printing is
4
PROTOCOL
allowed at any time before starting the
next communication.) For this operation,
the protocol monitor of one
communication is always buffered.
PARTIAL SRAM
5
Used to clear the SRAM.
CLEAR
Note: Executable only when the FAX is installed.
66-22
Purpose
Setting
Function
Handset sound volume adjustment (Japan only)
(Purpose)
Section
FAX
Item
Operation
Operation/procedure
1. Select the sound volume to be set.
(MAX: Large, MIDDLE: Medium, MIN: Small)
2. Press [START] key.
Selection of 1, 2, and 3 can be made even during execution of the sim-
ulation.
A sound is generated during execution of the simulation.
Note: Execution is possible only when FAX is installed.
66-24
Purpose
Data clear
Function
Used to clear the FAST storage data. (SEC only)
(Purpose)
Section
FAX
Item
Data
Operation/procedure
Select "1: YES" with the 10-key and press the [START] key. The FAST
storage data are cleared. (When "2: NO" is selected, the simulation is
canceled.)
Note: Executable only when the FAX is installed.
Content